Send Your Specs
Submit your specs, photos, drawings or BOM using the quote form.

FUSIBLE & NON-FUSIBLE DISCONNECTS
Safety switches and disconnects for commercial, industrial and emergency replacement jobs.
Send amperage, voltage, enclosure and fuse requirements.
Our team will review your details and reach out shortly — typically within 2 hours during business hours. Need it sooner? Call 1-800-905-2170.
Our Process
From quote to shipment, our process is built around speed, accuracy and clear communication.
Submit your specs, photos, drawings or BOM using the quote form.
Our team reviews your request and provides a fast, accurate quote.
We help source, build or match the right equipment for your project.
Equipment is carefully packaged and shipped nationwide.
Built For Your Project
Use this page for paid ad traffic and send the right customer into the right quote form.
Fusible safety switches for service and equipment applications.
Non-fusible disconnect options for local disconnecting means.
Indoor disconnect switches for controlled environments.
Outdoor rated disconnects for weather-exposed locations.
Heavy duty safety switches for commercial and industrial use.
Help matching damaged or obsolete equipment.
Category-Specific Specs

Quality You Can Trust
When a service disconnect fails on a live commercial feeder, the building goes dark and the clock starts. Verified Breakers stocks heavy-duty safety switches and service disconnects from 200 amp through 1200 amp and beyond across every major brand — Square D, Siemens, Eaton, Cutler Hammer, ABB, and GE — ready to ship inside 24 to 48 hours when manufacturer lead times stretch past 20 weeks.
A disconnect (also called a safety switch, service disconnect, or main disconnect) gives electrical contractors and facility teams a single-throw means of isolating an electrical circuit for maintenance, fault clearing, or lockout/tagout. Every commercial and industrial service requires a means of disconnect at the service entrance, at motor loads above defined horsepower thresholds, and at any equipment that needs to be serviced without de-energizing the entire panel.
Our inventory covers the full commercial and industrial range. We do not stock the 30, 60, or 100 amp homeowner-grade switches you find at a hardware store — every disconnect in our catalog is sized for B2B procurement: data center service entrances, manufacturing line feeders, HVAC plant, motor control centers, generator transfer points, and switchboard tie-ins.
The first procurement decision on any disconnect is whether you need overcurrent protection built into the switch or only isolation.
Fusible disconnects accept Class J, Class R, or Class L time-delay fuses depending on amp rating, providing both isolation and overcurrent protection in a single enclosure. Class J is the standard pick for new commercial work because of the smaller footprint and current-limiting performance. Class R is common on retrofit jobs where the existing fuse clips dictate the type. Class L is the choice on larger frame sizes from 601 amp upward.
Non-fusible disconnects provide isolation only and are used downstream of an existing overcurrent device — typically a feeder breaker in a panelboard or switchboard. Non-fusible units are the right call when the upstream breaker already handles short-circuit and overload protection and the local switch only needs to satisfy the NEC working-space and means-of-disconnect requirements.
Heavy-duty (HD) safety switches are the standard on commercial and industrial installations. They are rated for 200,000 AIC with the correct fuse, carry voltage ratings to 600V AC, and use a quick-make / quick-break mechanism that handles the higher fault currents found on three-phase systems. Every disconnect we stock is heavy-duty unless explicitly noted.
General-duty (GD) switches are 240V single-phase only and are not appropriate for the commercial three-phase loads our customers source. If a spec calls for general-duty equipment, the install is almost certainly outside our wheelhouse.
When a disconnect is the first means of disconnect after the utility service drop, it must be service entrance rated. Service entrance rated disconnects ship with a factory-installed neutral assembly bonded to the enclosure and meet UL 869A. Eaton's DH-EM series, Square D's H-frame service entrance models, and Siemens HF service rated variants are stocked across the common amp ratings. If the panel schedule calls for SE-rated, specify it on the quote request — the wrong neutral bond on a service entrance disconnect will fail inspection.
Safety switches ship in the full NEMA enclosure range so the switch matches the install environment without field modification:
Voltage classes span 240V, 480V, and 600V AC three-phase. Pole configurations include two-pole, three-pole, and four-pole — the four-pole option is typical when a switched neutral is required for a separately derived system or a transfer switch application.
Our disconnect inventory runs from 200 amp commercial service work up through 1200 amp main switchboard feeders, with larger frame sizes available on emergency build. Each amp rating has its own collection page with brand-specific availability and lead times:
Between standard frame sizes, 200 amp, 400 amp, and 800 amp variants are also stocked in matching brands and enclosures. Mixed-rating orders ship together to keep the install schedule on one delivery.
Every manufacturer specified on modern commercial drawings is represented in our inventory:
If your spec calls for a discontinued or hard-to-source catalog number, our procurement desk will locate, refurbish, or build a code-compliant equivalent. Brand cross-references are part of every quote.
Most quote requests we see fall into one of five buckets: data center service entrance and MCC feeders, manufacturing line and process loads, large commercial HVAC and rooftop equipment, generator transfer and paralleling gear, and emergency replacement work on existing switchboard lineups. Each application drives a different combination of amp rating, fuse class, enclosure type, and service entrance status — specify the application on the quote request and our team will confirm the correct configuration before shipping.
If a disconnect is on your panel schedule and the manufacturer just quoted a Q4 delivery, request a quote below. We will price the in-stock units that match your specification, confirm shipping window, and have the switch on a truck the same business day in most cases.